Snaplock installed by Roofing Group

System 05Roofing · Wall cladding · Soffits

Snaplock

Thin ribs and wide pans, in 25 mm and 38 mm modules, snapped closed by hand.

The profile

One pan,
a seam that snaps.

Snap lock panels clip over concealed clips and snap together along the seam, so no fixings pass through the sheet and no seaming machine is needed on site.

It reads like a standing seam, with a wide flat tray and a thin raised rib, and it installs faster. Two modules: a 25 mm rib in 320 or 520 mm pans, and a 38 mm rib in 285 or 485 mm pans, with custom widths made to suit the job.

SectionSnap lock, 38 mm rib on plywood deck
38 mmPan 285 or 485 mm01 Snap seam03 Concealed stainless clip02 PanWaterproof sarking over structural plywood
  • 01Snap seam38 mm or 25 mm rib, closed by hand with no seaming machine
  • 02Pan285 or 485 mm with the 38 mm rib, 320 or 520 mm with the 25 mm rib
  • 03Concealed clipStainless steel, min. 0.4 mm, countersunk to the substrate at max. 400 mm centres

38 mm rib

285 or 485 mm pans
Seam
Taller rib

The deeper rib reads as a firm shadow line across the roof, and pairs with the narrower pan modules.

25 mm rib

320 or 520 mm pans
Seam
Finer rib

A slimmer line with wider pans, so the face reads flatter. It suits walls and roofs where the rib should be a detail rather than a feature.

Why specify it

Five reasons architects
choose snaplock.

From the setting out on the drawings to the warranty at handover, this is what the system gives a project.

  1. Folding a snap lock edge in the workshop
    01

    Faster to install, and cheaper

    The seam closes by hand, so there is no seaming machine and no seaming crew. Fewer hours and less plant on site means a shorter roofing program and a lower install cost than a mechanically seamed roof.

  2. Folded edges coming off the line
    02

    Nothing pierces the sheet

    Every fixing sits under the seam on a concealed clip. There are no exposed screws and no sealed penetrations across the field of the roof, which removes the most common source of leaks.

  3. Pans on concealed clips over the deck
    03

    The metal is free to move

    The pan sits on the clip rather than being pinned to it, so it expands and contracts with the weather without loading the fixings. Long runs do not need expansion steps across the roof.

  4. Folded seam against snapped seam
    04

    Flatter trays, less oil canning

    Nothing is stressed closing the seam, so the tray keeps its shape. It is the difference you see across a wide pan in zinc or copper, where a folded seam can pull waviness into the face.

  5. The 25 mm rib against a 520 mm pan, to scale
    05

    Wide pans, thin ribs

    Pans run to 520 mm with a rib only 25 mm high, so the roof reads as broad flat planes rather than a run of ribs. Widths are made to order where a module has to land on something.

Technical details

The layers

Snap lock pans sit on clips screwed to a plywood deck over a breathable waterproof membrane. These are our standard layers, from the outside in.

  1. 01Snap lock panZinc 0.7 mm, copper 0.7 mm, aluminium 0.7 or 0.8 mm, Colorbond 0.55 or 0.7 mm
  2. 02Concealed clipsStainless steel, min. 0.4 mm, countersunk at max. 400 mm centres
  3. 03Waterproof sarkingFully breathable and waterproof
  4. 04Structural plywood18 mm for roofing, 15 mm for cladding
  5. 05Ventilated supportRigid and continuous, by others

Structure and insulation are by others. Clip spacing is confirmed for each project against the site’s wind loads.

Section through the wall layers. Not to scale.

Snaplock seam closed over a concealed clip

Specification
by metal.

  • Zinc runs to its own widths: 390 mm with the 38 mm rib and 420 mm with the 25 mm rib.
  • Custom widths are made to order for new work and for matching an existing roof.
  • Panels run 1 to 8 m, and longer where site access allows.
  • Panels run vertically or horizontally.
  • Dimensions carry a ±10 mm tolerance.
  • Aluminium is 3005 alloy, minimum H42 temper, PVDF coated over a primer with at least two paint layers.
Narrow it down in the Spec Builder
Snap lock by metal
MetalThicknessStandard panel width
Zinc (VMZINC)0.7 mm38 mm rib390mm25 mm rib420mm
Copper (Aurubis)0.7 mm38 mm rib285485mm25 mm rib320520mm
Aluminium (VESTIS, PVDF)0.7 or 0.8 mm38 mm rib285485mm25 mm rib320520mm
Colorbond and UniCote steel0.55 or 0.7 mm38 mm rib285485mm25 mm rib320520mm
Corten0.7 mm38 mm rib285485mm25 mm rib320520mm
Rib height
25 mm or 38 mm
Module sizes
25 × 320, 25 × 520, 38 × 285 and 38 × 485 mm. Zinc 38 × 390 and 25 × 420 mm. Custom widths on request
Panel length
1 to 8 m, longer subject to site access
Fixing
Concealed stainless steel clips, min. 0.4 mm, at max. 400 mm centres
Substrate
Ventilated, rigid and continuous: 15 mm plywood for cladding, 18 mm for roofing
Tolerance
Dimensions ±10 mm
Orientation
Vertical and horizontal
Applications
Roofing, Wall cladding, Soffits

Concealed
clips.

Each pan is held by stainless steel clips screwed to the deck under the seam. The next pan snaps over them, so nothing shows on the face and the metal is free to move.

Clips

Stainless steel, countersunk into a rigid, continuous substrate under the seam.

Min. 0.4 mm, max. 400 mm centres

Substrate

Ventilated plywood, thicker on roofs than on walls.

18 mm roofing, 15 mm cladding

Seam

Snapped closed by hand as each pan is laid, with no seaming machine.

38 mm or 25 mm rib

Details and
drawings.

Typical details for documentation. Select a drawing to view it full size, or download the full detail set.

  • Roof layers

    Snap lock over a ventilated cavity, with steel sheeting strips behind the seams and a minimum 40 mm airflow gap.

    Roofing Group detail, for illustration only

Literature

3 documents

Full detail sets

Eaves, ridge, valley, parapet, corner, window and penetration details as PDF, with the manufacturer data behind them.

Browse the library

How we deliver snaplock

  1. 01

    Review

    We check the drawings, exposure and buildability, and recommend the metal and gauge.

  2. 02

    Shop drawings

    Our drafters set out every pan, clip and junction for architect approval.

  3. 03

    Fabrication

    Panels are folded in our 2,000 m² Sydney workshop and QA checked before dispatch.

  4. 04

    Installation

    Our own crews install under a dedicated project manager, then hand over warranties.

Questions

11 answered

Snaplock questions

The questions estimators and drafters answer most often. If yours is not here, send the drawings and we will answer it against your project.

Ask about your project
What is a snap lock roof?

Snap lock is a concealed fix metal roof. Each pan is folded with a male and a female edge; the pan is laid over stainless steel clips and the next pan snaps down over the seam by hand. No fixings pass through the sheet and no seaming machine is used.

What is the difference between snap lock and standing seam?

A standing seam is folded closed on site with a seaming machine, which lets it go to very low pitches and follow curves and complex junctions. A snap lock seam snaps closed by hand, which is faster and leaves the tray flatter, so it shows less oil canning. Snap lock suits long, straightforward roofs and walls.

What is the minimum pitch for a snap lock roof?

Two degrees, with either rib. Below that we would move you to a double lock standing seam, which is folded closed on site and rated for lower pitches.

What rib heights does snap lock come in?

Two: 25 mm and 38 mm. The rib height sets the pan widths that go with it, so a 25 mm rib comes in 320 or 520 mm pans and a 38 mm rib in 285 or 485 mm pans.

How wide are snap lock pans?

Four standard modules: 25 × 320, 25 × 520, 38 × 285 and 38 × 485 mm. Zinc is the exception and runs at 390 mm with the 38 mm rib and 420 mm with the 25 mm rib. Custom widths are made to order, which is how we land a module on a ridge, a parapet or an existing roof. Dimensions carry a ±10 mm tolerance.

How is snap lock fixed?

On stainless steel clips at maximum 400 mm centres, a minimum 0.4 mm thick, countersunk into a rigid, continuous and ventilated plywood substrate over waterproof sarking. The substrate is 18 mm on roofs and 15 mm on walls. The clips sit inside the seam, so nothing shows on the face.

How long can snap lock panels be?

From 1 to 8 m as standard, and longer where the site can take the delivery and the lift. Single lengths avoid end laps across the roof.

Can snap lock be used on walls?

Yes. It runs vertically or horizontally as wall cladding, and the seam can carry on from the roof onto the wall as one continuous line.

Which metals can be used for snap lock?

Titanium zinc at 0.7 mm, copper at 0.7 mm, aluminium at 0.7 or 0.8 mm, Colorbond at 0.55 or 0.7 mm including the matt and metallic finishes, plus Zincalume, stainless steel, Corten and the UniCote LUX range. Aluminium must be 3005 alloy, minimum H42 temper, with a PVDF coating.

Does snap lock oil can?

Less than a folded standing seam, because the seam closes without stressing the tray. Oil canning also depends on pan width, metal thickness and how flat the deck is, so we set out the widths to suit the metal.

Can snap lock panels be curved?

Gentle curves are possible, but tight curves, tapers and complex junctions are better in standing seam, which is folded on site rather than snapped.

Next systemCassetteLarge folded trays on a concealed subframe, with a 20 mm recessed joint on all four sides.
All systems

Start your next project.

Send drawings or a brief. Concept sketches are enough to get a useful answer.

  1. You send drawings or a brief

    A plan, a section and an elevation are enough.

  2. 1business day

    An estimator replies

    Named contact, not a queue.

  3. 7days

    Tender returned

    Priced by system, metal and area.