Staggered joints
Wall and soffit- Seam
- Raised joints
The standard installation. Courses are offset so the joints break, which is what gives shingles their scale like read.

System 04Wall cladding · Soffits
Interlocking metal tiles, square, rectangular or diamond, on a 7 mm wall footprint.
7mm
System height
Off the face of the substrate
15mm
Minimum substrate
Continuous board, wrapped in membrane
4
Standard formats
Square, rectangle, wide and narrow diamond
590mm
Largest square
885 mm long in the rectangle format
The profile
Shingles are folded into interconnecting tile shapes with a formed welt on all four edges.
The lower edge of each panel engages the upper edge of the panel below, so every fixing is covered and nothing shows on the face. Panels are cut to size as squares, rectangles or diamonds, and the pattern is set by the sizes you choose. Because the whole system sits only 7 mm off the substrate it suits tight wall layers, and because each panel is small it wraps curves, cones and turrets that a long pan cannot follow.
The standard installation. Courses are offset so the joints break, which is what gives shingles their scale like read.
Joints line up course to course for a grid rather than a scale. Made to order, and not used on roofs.
Why specify it
From the setting out on the drawings to the warranty at handover, this is what the system gives a project.

Each panel is small enough to step around a tight radius without faceting, which is why shingles end up on domes, turrets, cones and double curves where a long pan cannot go.

The whole system stands 7 mm off the substrate. Where the wall is already tight, that is the difference between a metal facade and a compromise.

Square, rectangular, wide diamond or narrow diamond, from 193 mm up to 940 mm, and formats can be mixed across an elevation. The size you pick sets the scale of the facade.

Every clip is covered by the course above, so there are no exposed fixings and no sealant lines across the field.

Zinc and copper shingles are classified A1 for reaction to fire, and PIGMENTO and lacquered finishes A2. The whole assembly still has to be assessed, which we do per project.

The same panel runs across all three, so a form can be wrapped in one material without changing system at the eaves.
Technical details
Shingles hang on stainless clips fixed to a continuous board substrate. These are our standard layers, from the face inwards.
Structure and insulation are by others. Clip spacing and panel size are confirmed for each project against the site’s wind loads.
Section through the wall layers. Not to scale.

| Metal | Thickness | Standard panel width |
|---|---|---|
Zinc (VMZINC) | 0.7, 0.8 or 1.0 mm | 235420590 mm squaremm |
Copper (Aurubis) | 0.6, 0.7 or 0.8 mm | 235420590 mm squaremm |
Aluminium (VESTIS, PVDF) | 0.7 or 0.8 mm | 235420590 mm squaremm |
Colorbond and UniCote steel | 0.55 or 0.7 mm | 235420590 mm squaremm |
Each shingle is held by stainless steel clips along its upper edge. The course above covers them, so the face stays unbroken and the metal is free to move.
Stainless steel, two screws or nails into the board through each clip.
Max. 320 mm centres
Countersunk screws or ribbed stainless nails into the continuous board.
Screws 4 × 30 mm, nails 32 mm min.
Continuous construction grade board, wrapped in waterproofing membrane.
Min. 15 mm
Typical details for documentation. Select a drawing to view it full size, or download the full detail set.
Shingle cladding turning an internal corner, with the welt carried through the return.
Roofing Group detail, for illustration only
How a shingle elevation starts and finishes, with the welt closed at both ends.
Roofing Group detail, for illustration only
Literature
3 documents
Full detail sets
Eaves, ridge, valley, parapet, corner, window and penetration details as PDF, with the manufacturer data behind them.
Browse the libraryWe check the drawings, exposure and buildability, and recommend the metal and gauge.
Our drafters set out every pan, clip and junction for architect approval.
Panels are folded in our 2,000 m² Sydney workshop and QA checked before dispatch.
Our own crews install under a dedicated project manager, then hand over warranties.
Questions
10 answered
The questions estimators and drafters answer most often. If yours is not here, send the drawings and we will answer it against your project.
Ask about your projectFlat metal panels folded with an interlocking welt on all four edges. The lower edge of each panel engages the upper edge of the panel below, so the panels hang off each other and every fixing is covered. They are laid in courses like a tile or a slate.
Four standard formats. Squares at 235, 420 and 590 mm. Rectangles at 235 × 470, 235 × 940, 420 × 630, 420 × 840 and 590 × 885 mm. Wide diamonds at 274 × 215, 290 × 230 and 432 × 336 mm. Narrow diamonds at 371 × 193, 391 × 206 and 585 × 301 mm. Custom sizes are cut to order.
The system stands 7 mm off the face of the substrate, which is the thinnest of our facade systems. Behind that you need a continuous board of at least 15 mm and, in zinc, a ventilated cavity of 20 mm on walls or 40 mm on roofs.
On stainless steel clips along the upper edge of each panel, at a maximum of 320 mm centres, with two screws or nails through each clip into the board. The next course covers the clips, so nothing shows on the face.
We specify shingles for walls and soffits. Roofs are taken on case by case in the square and diamond formats, confirmed against the pitch and the manufacturer’s area of use table for the chosen metal. Rectangles stay on walls and soffits. Send the pitch and the roof plan and we will tell you either way.
Curved work is where shingles earn their place, because each panel is small enough to follow a dome, turret or cone without faceting. Curved roofs are quoted case by case on the pitch and the form.
They share the same interlocking welt. Flat lock is laid as larger rectangular panels for a flat, quiet facade; shingles are smaller and laid in courses, so the pattern itself becomes the finish.
Natural zinc, QUARTZ-ZINC, ANTHRA-ZINC, AZENGAR and copper are classified A1 for reaction to fire, and PIGMENTO and lacquered finishes A2. Compliance depends on the whole wall or roof assembly, which we confirm for each project.
Zinc at 0.7, 0.8 or 1.0 mm and copper at 0.6, 0.7 or 0.8 mm are the usual choices, and we also fold shingles in aluminium, Colorbond, UniCote, Corten and stainless steel.
Yes, on walls and soffits. Aligned flat joints give a grid rather than a scale pattern, and are made to order. Roofs use the standard staggered raised joints.
Send drawings or a brief. Concept sketches are enough to get a useful answer.
You send drawings or a brief
A plan, a section and an elevation are enough.
An estimator replies
Named contact, not a queue.
Tender returned
Priced by system, metal and area.