Interlocking Panel V25 Cladding, Sydney

Flat panels with express joints, in standard widths from 190 to 390 mm or made to suit the site.

The profile

Flat panels,
sharp shadow lines.

The V25 interlocking panel gives a flat facade broken by recessed express joints.

Each 25 mm deep panel hooks into the next and fixes through a concealed flange to galvanised top hats, so no fixings show, and the cavity behind works as a ventilated rainscreen. Standard widths run from 190 to 390 mm depending on the metal, widths can be mixed for a random coursing, and we fold custom widths to suit the site. We do not go wider than 390 mm, because wider flat trays start to show thermal distortion and oil canning.

SectionV25 interlocking panels on galvanised top hats
25 mmPanel 190 to 390 mm01 Interlocking panel02 Express joint, up to 18 mm03 Screwed through the extended leg, then coveredGalvanised top hat, waterproof sarking, wall by others
  • 01Interlocking panelA flat face folded to a 25 mm depth, 190 to 390 mm wide
  • 02Express jointA recessed shadow line between panels, from flush to 18 mm
  • 03Concealed fixingScrewed through a hidden flange into the top hat, then covered by the next panel

Horizontal

Walls and soffits
Top hats
Run vertically behind
Look
Long, low lines

Panels run across the facade and the express joints read as horizontal shadow lines.

Vertical

Walls and soffits
Top hats
Run horizontally behind
Look
Tall, slender lines

Panels run up the building for a finer, taller elevation. Widths can be mixed for a random coursing.

Why specify it

Six reasons architects
choose interlocking panel v25.

From the setting out on the drawings to the warranty at handover, this is what the system gives a project.

  1. Interlocking panels on a curved fascia, over a lined soffit
    01

    Flat face, crisp joints

    A smooth, flat facade broken only by recessed express joints, with no seams or fixings on show.

  2. Panelled blade and soffit, Alexandria Residence
    02

    A rainscreen, not a seal

    Water that passes the joints drains down the cavity without entering the wall, so the system stays waterproof without exposed mastics or sealants.

  3. Panels wrapping a curved entry canopy
    03

    Ventilated behind

    Air moves freely through the cavity formed by the top hats, drying the back of the panels and the wall behind.

  4. Panels landing on a timber reveal
    04

    Sized to the opening

    Panel widths are adjusted to land exactly on window and door openings, and joints can be set anywhere from flush to 18 mm.

  5. Panelled soffit over a balcony
    05

    Non-combustible metals

    Zinc, copper, aluminium and steel are listed as non-combustible materials under NCC 2022, clause C2D10.

  6. Cutting sheet to length, offcuts kept low
    06

    Little waste

    Panels are cut to length and folded in our workshop, so offcuts stay low and every panel arrives ready to fix.

Technical details

The layers

V25 panels fix to galvanised top hats on the wall, which form a ventilated cavity behind the facade. These are our standard layers, from the face of the building inwards.

  1. 01V25 interlocking panelZinc 1.0 mm, copper 0.9 mm, aluminium 0.8 mm or steel 0.55 mm
  2. 02Concealed fixingsThrough the panel flange at max. 500 mm centres, max. 100 mm from each panel end
  3. 03Galvanised top hats1.15 mm × 35 mm, at max. 500 mm centres, running across the panels
  4. 04Ventilated cavityThe depth of the top hats, open for air to move behind the panels
  5. 05Waterproof sarkingFully breathable and waterproof
  6. 06Wall structureBy others, able to take the top hat fixings

Main structure and insulation are by others. Top hat sizes and spacing are confirmed for each project against the site’s wind loads.

Section through the wall layers. Not to scale.

Interlocking panel V25 seam closed over a concealed clip

Specification
by metal.

  • Widths can be mixed for a random coursing. We do not go wider than 390 mm, because wider flat panels show thermal distortion and oil canning.
  • Panels run vertically or horizontally, with top hats running the opposite way.
  • Custom panel widths are available: we set them out to suit the site and the openings.
  • Panel length: talk to us at design stage.
  • Aluminium is 3005 alloy, minimum H42 temper, PVDF coated over a primer with at least two paint layers.
Narrow it down in the Spec Builder
Interlocking panel V25 by metal
MetalThicknessStandard panel width
Zinc (VMZINC)1.0 mm220390mm
Copper (Aurubis)0.9 mm220290390mm
Aluminium (VESTIS, PVDF)0.8 mm190290390mm
Colorbond and UniCote steel0.55 mm190290390mm
Standard widths
190 to 390 mm by metal; custom widths available
Maximum width
390 mm, to limit oil canning
Panel depth
25 mm
Express joint
Flush to 18 mm
Substructure
Galvanised top hats, 1.15 mm × 35 mm, at max. 500 mm centres
Fixings
Concealed, at max. 500 mm centres and max. 100 mm from panel ends
Sarking
Breathable waterproof sarking behind the top hats
Orientation
Horizontal or vertical
Applications
Wall cladding, Soffits

Concealed
fixings.

Each panel is screwed through a hidden flange into the top hats. The next panel hooks over that flange, covering the fixings and forming the express joint.

Top hats

Galvanised steel, fixed to the structure across the direction of the panels.

1.15 mm × 35 mm, max. 500 mm centres

Panel fixings

Through the concealed flange into every top hat the panel crosses.

Max. 500 mm centres, max. 100 mm from panel ends

Express joint

Set on site to suit the design, from a tight flush line to a deep shadow.

0 to 18 mm

Details and
drawings.

Typical details for documentation. Select a drawing to view it full size, or download the full detail set.

  • Wall cladding

    V25 panels on top hats over a brick wall, with a 5 mm caulked gap at the abutment.

    Roofing Group detail, for illustration only

  • Parapet capping

    Capping over roof boarding and a folded clip, with the panels finishing below. Minimum 1° fall on the capping.

    Roofing Group detail, for illustration only

  • Window junctions

    Head, jamb and sill flashings around a window, sealed with mastic compatible with zinc.

    Roofing Group detail, for illustration only

  • Outside angle

    An angle profile closing the external corner over the top hats.

    Roofing Group detail, for illustration only

  • Inside angle

    An internal corner finished with a continuous welt piece.

    Roofing Group detail, for illustration only

  • Fascia and soffit

    Panels wrapping a fascia and soffit, with parapet capping above and a 5 mm caulked gap.

    Roofing Group detail, for illustration only

Literature

5 documents

How we deliver interlocking panel v25

  1. 01

    Review

    We check the drawings, exposure and buildability, and recommend the metal and gauge.

  2. 02

    Shop drawings

    Our drafters set out every pan, clip and junction for architect approval.

  3. 03

    Fabrication

    Panels are folded in our 2,000 m² Sydney workshop and QA checked before dispatch.

  4. 04

    Installation

    Our own crews install under a dedicated project manager, then hand over warranties.

Questions

11 answered

Interlocking panel V25 questions

The questions estimators and drafters answer most often. If yours is not here, send the drawings and we will answer it against your project.

Ask about your project
What is an interlocking panel facade?

An interlocking panel facade is made of flat metal panels that hook into each other along their long edges. Each panel is screwed through a hidden flange into top hats on the wall, and the next panel covers the fixings, leaving a recessed express joint between them.

What does V25 mean?

V25 refers to the panel’s 25 mm depth. The face is flat, and the returns along each edge are folded to 25 mm, which gives the panel its stiffness and forms the express joint.

How wide are interlocking panels?

Standard widths depend on the metal: 220 or 390 mm in zinc, 220, 290 or 390 mm in copper, and 190, 290 or 390 mm in aluminium and steel. Widths can be mixed for a random coursing, and we make custom widths to suit the site. We do not go wider than 390 mm, because wider flat panels show thermal distortion and oil canning.

How wide is the express joint?

The joint between panels can be set from flush up to 18 mm. Wider joints read as a stronger shadow line across the facade.

How are interlocking panels fixed?

Panels are screwed through a concealed flange into galvanised top hats at a maximum of 500 mm centres, and no more than 100 mm from each panel end. The next panel hooks over the flange and hides the fixing.

Is an interlocking panel facade waterproof?

It works as a rainscreen. Water that gets past the joints drains down the ventilated cavity without entering the wall, and a breathable waterproof membrane sits behind the top hats as the second line of defence. No exposed mastics or sealants are needed.

What goes behind interlocking panels?

Galvanised top hats, 1.15 mm × 35 mm at a maximum of 500 mm centres, fixed across the direction of the panels, over a breathable waterproof membrane on the wall structure. The top hats form a ventilated cavity behind the panels.

Which metals can be used for interlocking panels?

We fold V25 panels in zinc (1.0 mm), copper (0.9 mm), aluminium (0.8 mm) and Colorbond or UniCote steel (0.55 mm). Aluminium must be 3005 alloy, minimum H42 temper, with a PVDF coating.

Can interlocking panels run vertically?

Yes. Panels run vertically or horizontally, with the top hats running the opposite way behind them.

Are interlocking metal panels non-combustible?

Zinc, copper, aluminium and steel are all listed as non-combustible materials in clause C2D10 of the NCC 2022. Compliance still depends on the whole wall assembly, including membranes and insulation, which we confirm for each project.

What is the difference between interlocking panels and cassettes?

Interlocking panels are long, narrow panels that hook together edge to edge. Cassettes are larger rectangular trays that hang on a subframe with a recessed joint on all four sides. See our cassette system page for details.

Next systemFlat lockA flat skin with a fine recessed joint, folded and interlocked on all four edges.
All systems

Start your next project.

Send drawings or a brief. Concept sketches are enough to get a useful answer.

  1. You send drawings or a brief

    A plan, a section and an elevation are enough.

  2. 1business day

    An estimator replies

    Named contact, not a queue.

  3. 7days

    Tender returned

    Priced by system, metal and area.