Horizontal
Walls and soffits- Top hats
- Run vertically behind
- Look
- Long, low lines
Panels run across the facade and the express joints read as horizontal shadow lines.

System 02Wall cladding · Soffits
Flat panels with express joints, in standard widths from 190 to 390 mm or made to suit the site.
25mm
Panel depth
Flat face, folded returns
18mm
Express joint up to
From flush to 18 mm
500mm
Maximum fixing centres
Into galvanised top hats
390mm
Maximum panel width
Standard widths from 190 mm, by metal
The profile
The V25 interlocking panel gives a flat facade broken by recessed express joints.
Each 25 mm deep panel hooks into the next and fixes through a concealed flange to galvanised top hats, so no fixings show, and the cavity behind works as a ventilated rainscreen. Standard widths run from 190 to 390 mm depending on the metal, widths can be mixed for a random coursing, and we fold custom widths to suit the site. We do not go wider than 390 mm, because wider flat trays start to show thermal distortion and oil canning.
Panels run across the facade and the express joints read as horizontal shadow lines.
Panels run up the building for a finer, taller elevation. Widths can be mixed for a random coursing.
Why specify it
From the setting out on the drawings to the warranty at handover, this is what the system gives a project.

A smooth, flat facade broken only by recessed express joints, with no seams or fixings on show.

Water that passes the joints drains down the cavity without entering the wall, so the system stays waterproof without exposed mastics or sealants.

Air moves freely through the cavity formed by the top hats, drying the back of the panels and the wall behind.

Panel widths are adjusted to land exactly on window and door openings, and joints can be set anywhere from flush to 18 mm.

Zinc, copper, aluminium and steel are listed as non-combustible materials under NCC 2022, clause C2D10.

Panels are cut to length and folded in our workshop, so offcuts stay low and every panel arrives ready to fix.
Technical details
V25 panels fix to galvanised top hats on the wall, which form a ventilated cavity behind the facade. These are our standard layers, from the face of the building inwards.
Main structure and insulation are by others. Top hat sizes and spacing are confirmed for each project against the site’s wind loads.
Section through the wall layers. Not to scale.

| Metal | Thickness | Standard panel width |
|---|---|---|
Zinc (VMZINC) | 1.0 mm | 220390mm |
Copper (Aurubis) | 0.9 mm | 220290390mm |
Aluminium (VESTIS, PVDF) | 0.8 mm | 190290390mm |
Colorbond and UniCote steel | 0.55 mm | 190290390mm |
Each panel is screwed through a hidden flange into the top hats. The next panel hooks over that flange, covering the fixings and forming the express joint.
Galvanised steel, fixed to the structure across the direction of the panels.
1.15 mm × 35 mm, max. 500 mm centres
Through the concealed flange into every top hat the panel crosses.
Max. 500 mm centres, max. 100 mm from panel ends
Set on site to suit the design, from a tight flush line to a deep shadow.
0 to 18 mm
Typical details for documentation. Select a drawing to view it full size, or download the full detail set.
V25 panels on top hats over a brick wall, with a 5 mm caulked gap at the abutment.
Roofing Group detail, for illustration only
Capping over roof boarding and a folded clip, with the panels finishing below. Minimum 1° fall on the capping.
Roofing Group detail, for illustration only
Head, jamb and sill flashings around a window, sealed with mastic compatible with zinc.
Roofing Group detail, for illustration only
An angle profile closing the external corner over the top hats.
Roofing Group detail, for illustration only
An internal corner finished with a continuous welt piece.
Roofing Group detail, for illustration only
Panels wrapping a fascia and soffit, with parapet capping above and a 5 mm caulked gap.
Roofing Group detail, for illustration only
Literature
5 documents
Full detail sets
Eaves, ridge, valley, parapet, corner, window and penetration details as PDF, with the manufacturer data behind them.
Browse the libraryWe check the drawings, exposure and buildability, and recommend the metal and gauge.
Our drafters set out every pan, clip and junction for architect approval.
Panels are folded in our 2,000 m² Sydney workshop and QA checked before dispatch.
Our own crews install under a dedicated project manager, then hand over warranties.
Questions
11 answered
The questions estimators and drafters answer most often. If yours is not here, send the drawings and we will answer it against your project.
Ask about your projectAn interlocking panel facade is made of flat metal panels that hook into each other along their long edges. Each panel is screwed through a hidden flange into top hats on the wall, and the next panel covers the fixings, leaving a recessed express joint between them.
V25 refers to the panel’s 25 mm depth. The face is flat, and the returns along each edge are folded to 25 mm, which gives the panel its stiffness and forms the express joint.
Standard widths depend on the metal: 220 or 390 mm in zinc, 220, 290 or 390 mm in copper, and 190, 290 or 390 mm in aluminium and steel. Widths can be mixed for a random coursing, and we make custom widths to suit the site. We do not go wider than 390 mm, because wider flat panels show thermal distortion and oil canning.
The joint between panels can be set from flush up to 18 mm. Wider joints read as a stronger shadow line across the facade.
Panels are screwed through a concealed flange into galvanised top hats at a maximum of 500 mm centres, and no more than 100 mm from each panel end. The next panel hooks over the flange and hides the fixing.
It works as a rainscreen. Water that gets past the joints drains down the ventilated cavity without entering the wall, and a breathable waterproof membrane sits behind the top hats as the second line of defence. No exposed mastics or sealants are needed.
Galvanised top hats, 1.15 mm × 35 mm at a maximum of 500 mm centres, fixed across the direction of the panels, over a breathable waterproof membrane on the wall structure. The top hats form a ventilated cavity behind the panels.
We fold V25 panels in zinc (1.0 mm), copper (0.9 mm), aluminium (0.8 mm) and Colorbond or UniCote steel (0.55 mm). Aluminium must be 3005 alloy, minimum H42 temper, with a PVDF coating.
Yes. Panels run vertically or horizontally, with the top hats running the opposite way behind them.
Zinc, copper, aluminium and steel are all listed as non-combustible materials in clause C2D10 of the NCC 2022. Compliance still depends on the whole wall assembly, including membranes and insulation, which we confirm for each project.
Interlocking panels are long, narrow panels that hook together edge to edge. Cassettes are larger rectangular trays that hang on a subframe with a recessed joint on all four sides. See our cassette system page for details.
Send drawings or a brief. Concept sketches are enough to get a useful answer.
You send drawings or a brief
A plan, a section and an elevation are enough.
An estimator replies
Named contact, not a queue.
Tender returned
Priced by system, metal and area.