Systems | | 7 min read
Standing seam roofing: a specifier's guide to seams, clips and pitch
Standing seam roofing explained for specifiers: single vs double lock seams, pan widths, clips, thermal movement, minimum pitch and shop drawings.

Standing seam roofing is the reference system for architectural metal roofs. Long pans run from ridge to eave, joined by raised seams and fixed with concealed clips. There are no exposed fixings through the weather surface, and the metal is free to move.
Seam type, pan width, clip layout, pitch, substrate and detailing all interact, so specifiers should resolve them early. The notes below come from how we fabricate and install standing seam roofs in Sydney and across NSW.
How a standing seam system works
Each pan has an upstand on both edges. Adjacent pans overlap at the upstands, which are then folded together to form the seam. Our standard seam height is 25 mm.
Clips sit under the seam and are fixed to the substrate. The clip holds the pan without penetrating it, so the roof can take up thermal movement without stressing fixings or tearing holes.
The system can be formed in zinc, copper, aluminium, Colorbond, UniCote and Corten. Our standing seam system page shows the range of materials and finishes.
Single lock vs double lock standing seam
The seam fold sets the weather performance of the roof or wall, so choose it first.
Double lock standing seam
In a double lock standing seam, the upstands are folded over twice, through 180 degrees and then again. The result is a tight, compact seam with high resistance to water penetration and wind uplift.
Double lock is our standard for roofs. It is commonly used where low pitches are required, because the double fold resists water being driven or ponding against the seam. Minimum pitch depends on the material, the seam and the manufacturer, so confirm it with the manufacturer’s current technical guide.
Single lock standing seam
A single lock seam is folded once, through 90 degrees. It is quicker to form and gives a slightly softer line.
Single lock is our standard for walls and facades, where water runs off vertically and does not pond. Green Square Apartments uses VMZINC Pigmento Blue and Red in single lock standing seam on the facade.
| Feature | Double lock | Single lock |
|---|---|---|
| Fold | Folded twice (180 degrees plus) | Folded once (90 degrees) |
| Typical use | Roofs, including low pitch | Walls and facades, steeper roofs |
| Weather resistance | Higher | Adequate for vertical and steep surfaces |
| Seam profile | Tight and compact | Slightly fuller |
| Pitch | Suitable for lower pitches (confirm with manufacturer) | Steeper pitches only |
Pan widths and oil canning
Pan width affects appearance, wind performance and flatness. Narrower pans are stiffer and show less waviness across the flat. Wider pans give a broader, calmer rhythm but are more prone to visible distortion.
That waviness is known as oil canning. It is a visual characteristic of flat metal, not a structural defect. It is influenced by pan width, material thickness, substrate flatness and thermal movement. Our oil canning guide explains the causes and how to reduce them.
Wind loading also affects pan width. In high wind zones and at roof edges and corners, narrower pans and closer clip spacing are commonly specified. Confirm clip spacing with the engineer and the manufacturer’s data for the site wind classification.
Clips and thermal movement
Metal expands and contracts with temperature. A long pan on a hot Sydney afternoon can grow noticeably compared with a cold morning. The system must allow for this.
Fixed and sliding clips
We use concealed stainless steel clips. Two types work together:
- Fixed clips lock the pan in position over a defined zone, typically near the ridge or the middle of the run.
- Sliding clips hold the pan against wind uplift but allow it to move lengthwise.
The fixed zone and the direction of movement must be set out on the shop drawings. Flashings at the eave and ridge must allow the pan to move without binding.
Pan length
Very long pans increase total movement and may need expansion joints or steps. Maximum length depends on the metal, its expansion rate and the fixing layout. Resolve this at design stage, not on site.
Minimum pitch
Standing seam roofs perform well at low pitches, but they are not flat roofs. Each manufacturer publishes a minimum pitch for each seam type and material. Double lock seams are generally rated for lower pitches than single lock.
A roof designed at the absolute minimum pitch may end up below it after the frame settles, so allow a margin for construction tolerance and structural deflection. Confirm the minimum pitch with the manufacturer’s current technical guide and check the relevant requirements of the NCC and AS/NZS 1562.1.
Substrate and assembly
The substrate supports the clips and the pans. It must be flat, stable and suited to the metal.
- Continuous substrate: plywood or similar boarding gives a flat support and is common for zinc and copper. It helps reduce oil canning.
- Battens or purlins: used with some systems and materials, subject to manufacturer guidance on spacing and pan thickness.
- Underlay and membrane: a breathable membrane or structured underlay manages condensation and provides a secondary barrier.
- Ventilation: zinc in particular needs a ventilated or breathable roof or wall so moisture does not sit against the underside.
Check that the substrate, underlay and clips are compatible with the chosen metal. Zinc, for example, should not sit against materials that produce acidic runoff.
Curved standing seam
Standing seam pans can be curved, both convex and concave. Pans can also run vertically, horizontally or diagonally on walls.
Curving can be done by crimping, rolling or forming, depending on the radius and material. Tight radii may need pans pre curved in the factory. Barrel roofs and curved fascias are common applications.
Curved work needs accurate setting out. Our own team prepares shop drawings and pre curves pans in our 2,000 m² fabrication facility, using CNC folding and press brakes.
Detailing the edges
Leaks and movement faults on standing seam roofs usually trace back to edges and junctions. Resolve these details on the drawings:
- Eaves: drip edge, gutter interface and allowance for pan movement.
- Ridge and hips: ventilated ridge where required, and closure of the seam ends.
- Valleys: sized for flow, with correct laps and movement allowance.
- Penetrations: flues, vents and skylights, preferably grouped to reduce seam cuts.
- Parapets and abutments: upstands, cappings and counter flashings.
- Dissimilar metals: separate incompatible metals and avoid copper runoff onto zinc or aluminium.
Shop drawings
Shop drawings turn the architect’s intent into fabrication data. They set pan widths, seam positions, clip zones, flashings and junctions. They also flag conflicts between the design and the manufacturer’s limits before material is cut.
Roofing Group prepares its own shop drawings, and our drafting team works directly with our fabrication team, so details are buildable. Recent standing seam roofs include Botanica in Ryde (VMZINC Anthra) and Erskineville Residence (VMZINC Quartz+). Browse more in our projects.
Send us your roof drawings
If you are specifying a standing seam roof, send us your drawings for early shop drawing advice. We can confirm seam type, pan widths and clip layout for your site. Contact Roofing Group or call 02 9725 1545. You can also draft a specification with our Spec Builder.