Oil canning in metal cladding: causes, tolerances and prevention

Oil canning in metal cladding explained: what causes waviness in flat panels, how to assess it, and the design choices that reduce it.

Flat dark zinc standing seam roof plane in raking light, showing how flat the pans read

Oil canning is visible waviness in the flat areas of a metal panel. It shows as soft ripples, dimples or a quilted look across the pan. It can appear on zinc, copper, aluminium, Colorbond, stainless steel and Corten, and on standing seam roofs, interlocking panels and flat flashings.

Oil canning is an aesthetic condition. A correctly installed system with some waviness still sheds water, resists wind load and lasts as long as a flat one. Manufacturers generally exclude oil canning from material warranties for this reason. The most effective controls are panel width, substrate and clip layout, and all three are set before fabrication starts.

What oil canning looks like

Every flat sheet carries small internal stresses. They make the sheet bow in or out between seams or folds. Under raking light, these bows read as shadows and highlights. The pattern shifts through the day as the sun moves and the metal heats and cools.

Common signs include:

  • Ripples running along the length of a pan between two seams.
  • A single panel that looks sucked in or pushed out compared with its neighbours.
  • Waviness that appears in the afternoon and fades by evening.
  • Reflections that bend across a facade.

Bright, reflective finishes show oil canning most. Pre-weathered zinc, patinated copper, matt coatings and textured finishes hide it better.

What causes oil canning

Oil canning usually results from several small factors adding together.

Thermal movement

Metal expands as it heats and contracts as it cools. A dark panel in direct Sydney sun runs well above air temperature. If the panel cannot slide along its length, the stress releases sideways as waviness. Concealed clips and sliding fixings let panels move. Fixed points in the wrong place, or clips set too tight, restrict that movement.

Substrate flatness

A thin sheet follows the surface behind it. Uneven battens, top hats out of plane, bowed framing and proud screw heads all show through the panel face.

Panel width and thickness

Wider pans have more unsupported flat area, so they show more waviness. Thinner sheet has less stiffness to resist it. Roofing Group fabricates interlocking panels in 190, 290 and 390 mm widths and does not go wider than 390 mm. That limit keeps thermal distortion and oil canning in check.

Fixing restraint and installation

Overdriven fixings, clips pulled hard against the seam and panels forced into place all lock in stress. A panel sprung or twisted to fit an out of square opening will often oil can once fixed.

Coil stress

Metal coil carries residual stress from rolling, slitting and levelling at the mill. Flatness varies from coil to coil. Tension levelling at the mill generally improves flatness, but no process removes stress entirely. Lifting a long panel by one end on site can add more.

How to reduce oil canning

Design lever What to specify Typical effect
Panel width Interlocking panels at 190, 290 or 390 mm (not wider than 390 mm) Narrower pans show less waviness
Panel length Within about 6 m for zinc, copper and aluminium; about 9 m for Colorbond, stainless and Corten Limits total thermal movement per panel
Material thickness Heavier gauge where the system and budget allow Stiffer sheet resists buckling
Stiffening Striations or micro ribs in the pan, where the system offers them Breaks up flat areas and masks minor waviness
Substrate Top hats (usually 1.15 mm galvanised) at max 600 mm centres, set true Removes a major source of show through
Fixing Concealed stainless clips set for expansion, spaced to suit wind load Panel moves without locking in stress
Finish Matt, pre-weathered or textured Lowers the contrast of ripples

Design and detailing

Settle panel width and finish with your installer during design development. A 190 mm interlocking panel will generally look flatter than a 390 mm panel in the same metal. On a standing seam roof, narrower pans between the 25 mm seams have the same effect. If the design calls for a wide, flat pan, consider a thicker sheet or a stiffened profile.

Flashings need the same attention. Roofing Group conceal fixes flashings and allows for thermal expansion so long lengths do not buckle.

Substrate and framing tolerances

Ask the builder to check framing and top hats for plane before cladding starts. Set top hats at no more than 600 mm centres, with a breathable membrane behind them. Pack any battens that sit out of line. Allowable deviation varies by system, so confirm it with the manufacturer’s current technical literature.

Lighting and viewing angle

Grazing light exposes every ripple. Low western sun and uplights mounted close to a wall both skim the face at a shallow angle. Where you can, set wall lights further off the face or light the facade from the front. Check how the elevation reads from the street as well as in close up renders.

Assessing oil canning on site

All flat metal cladding shows some waviness. An assessment asks whether the waviness is within what the specified system, metal and finish would normally produce.

Assess under fair conditions:

  • Viewing distance: stand at a normal viewing position, such as ground level or the street, not on a ladder at arm’s length.
  • Lighting: assess in diffuse daylight, not under low raking sun or grazing artificial light at night.
  • Time of day: note when the effect appears. Waviness that comes and goes with temperature is usually thermal.
  • Angle: view square to the face as well as along it. Sighting down the length of a wall exaggerates any ripple.
  • Comparison: compare with the approved sample or mock up panel.

Photograph concerns and note the date, time, weather and viewing position. The installer can then trace the cause. Waviness from a substrate out of plane or a restricted clip can often be corrected. Waviness from coil stress or thermal movement alone is generally accepted as a property of the material.

A mock up panel on site lets the architect, builder and owner agree an acceptable appearance before full production.

Checklist

  • Keep interlocking panels at 390 mm wide or narrower; choose 190 or 290 mm where flatness matters most.
  • Keep panel lengths within about 6 m (zinc, copper, aluminium) or 9 m (Colorbond, stainless, Corten).
  • Specify top hats at max 600 mm centres, checked for plane, with a breathable membrane behind.
  • Use concealed stainless clips that allow for expansion.
  • Choose matt, pre-weathered or textured finishes where a flat look is critical.
  • Avoid lighting that grazes flat metal faces.
  • Agree a mock up panel and assess from normal viewing distance in diffuse daylight.

Next step

Roofing Group’s own drafting team sets out panel widths, clip layouts and top hat spacing for each project, and our 2,000 m² Sydney facility folds the panels to suit. Send drawings for a shop drawing review and we will mark up widths and clip centres before fabrication. For system details see interlocking panels and standing seam, compare zinc and aluminium, or start a specification in the spec builder.