Skip to content

Materials | | 5 min read

Is a metal roof noisy, hot, or easy to dent?

The three objections clients raise about metal roofs, answered honestly: what is true, what depends on the assembly, and what is a myth.

Waterfront residence with a metal roof and cladding, seen from the water

These three come up in almost every residential conversation, usually from the client rather than the architect. They are worth answering properly, because two of them have a real basis and one does not.

“It will be loud in the rain”

Partly true, and entirely dependent on what is underneath.

The noise people remember is a shed or a verandah: profiled steel screwed to purlins with nothing behind it. The sheet is a drum skin stretched over air, and rain on it is loud because there is nothing to absorb the energy.

An architectural metal roof is a different construction. Our systems sit on a continuous deck, 17 or 18 mm structural plywood, over a breathable membrane, with insulation and a ceiling below. There is no drum. The plywood damps the impact at the point it happens, and each subsequent layer takes more out.

In practice a zinc or copper roof on a ply deck is quieter than a tile roof, because tiles rattle against each other and metal on ply does not.

What still makes noise: a roof fixed directly to battens with an air gap behind, a light gauge sheet over a large unsupported span, or rain onto an uninsulated metal lined soffit or canopy. If a canopy is over a bedroom window, that is worth a conversation.

“It will dent”

True of some metals, less of others, and largely a question of thickness and what is hitting it.

Hail is the real test. A 0.55 mm Colorbond sheet will mark from severe hail. A 0.7 mm zinc or 0.8 mm aluminium pan is noticeably more resistant, simply because there is more metal. Thickness is the main variable and it is one you control at specification.

Foot traffic is the other. Any metal roof will mark if trades walk on it carelessly, which is why access is worth designing: a walkway, a defined route to the plant, and a rule that nobody walks in the pan centre.

The thing that genuinely distinguishes zinc and copper: small scratches close over. Both metals protect themselves with a patina, and where the surface is broken the patina forms again across the scratch over months. It will not remove a dent, because nothing removes a dent, but a scuff during construction does not stay visible for the life of the building. On painted steel it does.

And because these systems are panelised, a damaged pan is a replaceable piece rather than a roof wide problem. On snap lock in particular a pan can be unclipped and swapped without disturbing the ones either side.

“It will make the house hot”

This is the myth of the three.

A dark metal roof gets hot on the surface. So does a dark tile roof, and so does dark anything. What reaches the room below is decided by the insulation, not the finish. Metal is thin, so it has almost no thermal mass: it heats fast and it sheds that heat fast the moment the sun goes off it. A masonry tile holds heat and radiates it into the roof space for hours after sunset.

Two things in the assembly matter more than the metal:

The ventilated cavity. Our facade assemblies run a cavity behind the panels: 20 mm on walls, 40 mm on roofs in zinc. It is there to keep the back of the metal dry, but it also lets hot air move out rather than sit against the structure.

The colour and the coating. If solar gain is a real concern, that is a finish decision. Lighter finishes and the higher reflectance Colorbond and UniCote ranges make a measurable difference, and they cost nothing extra to specify.

Where metal genuinely helps: it sheds summer heat quickly in the evening, and on a shallow roof it does not hold water, so there is no evaporative load on the structure.

What we would actually worry about

If you are weighing a metal roof, these are the questions worth more attention than the three above:

  • Ventilation behind the metal. Get this wrong on zinc and you get white rust, which is a real failure rather than an aesthetic one.
  • The corrosion zone. Distance from the surf decides which metals and coating classes are appropriate.
  • Dissimilar metals in the detail. A copper roof draining into a zinc gutter will fail regardless of how well either piece is made.
  • Who walks on it afterwards. Solar, air conditioning and antennas arrive after handover and are fixed by people who never saw the specification.

Those four cause real problems. Noise, dents and heat are mostly assembly questions that are settled by the time the roof is drawn.

If a client has raised one of these, send us the section and we will tell you what the assembly does about it. See cleaning and maintenance for what a metal roof needs over its life, and zinc ventilation and substrates for the assembly that keeps it dry.

Start your next project.

Send drawings or a brief. Concept sketches are enough to get a useful answer.

  1. You send drawings or a brief

    A plan, a section and an elevation are enough.

  2. 1business day

    An estimator replies

    Named contact, not a queue.

  3. 7days

    Tender returned

    Priced by system, metal and area.