The joint is the facade: shadow lines in metal cladding
How the joint between metal cladding panels sets the look of a building: express joints, recessed joints, raised seams and flush welts compared.

Choose a metal and you have chosen a colour and a lifespan. Choose a joint and you have chosen what the building looks like.
Every concealed fix metal system solves the same problem, which is how to hold a sheet of metal onto a wall without putting a screw through the face. What separates them is what that solution leaves behind on the elevation. At twenty metres you cannot see a clip, a welt or a top hat. You can see the line between one panel and the next, and on a large facade that line is most of the design.
Four families of line
A raised seam. Standing seam, snaplock, nailstrip and batten seam all leave a rib standing proud of the face, from 25 mm up to a 60 mm batten. The rib catches light down its full length, so it reads as a bright edge against a shaded panel and the elevation gets a strong directional grain. The deeper the rib, the further away it reads.
An open shadow. Interlocking panels leave an express joint, anywhere from flush to 18 mm. Nothing stands proud; the line is a void. At 18 mm it reads as a dark band and the wall becomes a series of planks. At 6 mm it is a crisp line and the wall stays a plane.
A recess on all four sides. A cassette is set apart from its neighbours on every edge, so the joint reads horizontally and vertically at once. This is the only system on the list that gives a true grid rather than a run, and it is why cassettes turn up on buildings where the facade is meant to read as a set of large tiles.
Almost no line at all. Flat lock and shingles leave a fine welt where one panel hooks into the next. Nothing stands off the face and there is no void. Up close you see a hairline; at distance the panels merge into one surface.
What the joint width does
On an open joint, three things move together as you widen it.
The elevation gets more horizontal or vertical emphasis, because the eye starts grouping the shadow with the panel next to it. The apparent panel width changes even though the panel has not: a 290 mm panel at a flush joint reads narrower than the same panel at 18 mm.
Tolerance gets easier. An 18 mm shadow absorbs a couple of millimetres of movement in the structure behind. A flush joint shows everything, which puts the work back onto the framing.
And you start seeing the cavity. Past about 10 mm, whatever is behind the panel line becomes part of the design, so we run a dark backing so the joint reads as depth rather than as a gap.
Where the light falls
The same joint does different things on different elevations, and it is worth walking the site before committing.
A north facing wall in Sydney gets direct sun for most of the day, so a raised seam throws a hard shadow and a recessed joint reads dark and crisp. A south facing wall sits in diffuse light, where a 6 mm express joint can almost disappear and a deeper joint or a raised seam does the work instead.
A soffit is lit from below by reflected light, which flattens everything. It is the one place where a flush system reads at its best, because there is no raking light to show a ripple and no strong shadow to lose the joint in.
Mixing systems on one building
There is nothing wrong with changing system across a building, as long as the change is deliberate. A common arrangement is standing seam on the roof and upper levels for the grain, and flat lock or interlocking panels at ground level where people are close enough to read a fine joint.
What does not work is two systems with similar but not matching joint widths on the same plane. A 12 mm express joint next to a 20 mm cassette recess reads as a mistake rather than a decision. If the systems change, change them at a corner, a setback or a floor level so the eye reads a break.
Questions we get asked
Which joint hides construction tolerance best? A wide express joint or a cassette recess. Both give you a shadow deep enough to absorb a few millimetres. Flush systems show everything, so they need the framing right.
Can I get a flush joint and still have a large panel? Not really. Large flat panels show distortion, which is why we cap interlocking panels at 390 mm wide. If you want a large module, a cassette with a recessed joint is the system, and the recess is part of the deal.
Does joint width affect weathering? It affects where water runs and where dirt collects. A deep horizontal recess catches more than a vertical one. On patinating metals that shows up as streaking below the joint, which some designs want and some do not.
What is the widest express joint you would recommend? 18 mm as standard. Past that the backing and the cavity become the visible part of the facade, and the detail behind has to be designed rather than just specified.
Can the joint width change across an elevation? Yes, and it can be an effective move: a tighter joint in the field and a wider one at a setback, for instance. It has to be drawn, because the setting out changes with it.
How early do you need this decided? Before fabrication, which in practice means before the shop drawings are signed off. Joint width sets the panel setting out, and the setting out sets every cut in the workshop.