Specification | | 7 min read
Interlocking panels vs cassette facades: choosing a flat panel metal system
Interlocking panel cladding compared with cassette systems: the look, joints, panel sizes, substructure, oil canning and what drives cost.

Architects asking for a flat, crisp metal wall usually end up choosing between two systems. Interlocking panel cladding gives long, linear panels with fine shadow joints. A cassette cladding system gives larger, tray formed panels with deeper recessed joints and a more monolithic look.
Both are flat panel metal facade systems with concealed fixings. They differ in joint expression, panel size, substructure and cost.
Interlocking panels at a glance
Interlocking panels are long, narrow trays with folded edges. Each panel clips over the one before it, hiding the fixings in the joint. The result is a linear rhythm with a tight shadow line between panels.
Our V25 interlocking panel comes in 190, 290 and 390 mm cover widths. It can be installed vertically, horizontally or diagonally. We do not make panels wider than 390 mm, to limit oil canning. Lengths run up to about 6 m in zinc, copper and aluminium, and about 9 m in Colorbond, UniCote and Corten. Panels fix to top hat battens at maximum 600 mm centres, and a breathable membrane behind them is recommended. See our interlocking panel system page for details.
Cassette panels at a glance
Cassette panels are trays folded on all four sides. They hang on a subframe using concealed fixings, with open or recessed joints between them. The panel reads as a flat plane, framed by a crisp shadow.
Our cassette system uses 20 mm recessed joints. It is a common alternative to aluminium composite panel for projects that want the same flat, large format look in solid metal. See our cassette system page for finishes and details.
Side by side comparison
| Criterion | Interlocking panel (V25) | Cassette |
|---|---|---|
| Visual character | Linear, directional rhythm | Grid of flat planes, monolithic |
| Joint | Fine shadow line in one direction | 20 mm recessed joints on all sides |
| Panel size | 190 to 390 mm wide, long lengths | Larger formats, set by material and design |
| Orientation | Vertical, horizontal or diagonal | Grid layout, horizontal or vertical emphasis |
| Fixing | Concealed in the interlock | Concealed on the subframe |
| Substructure | Top hat battens, max 600 mm centres | Engineered subframe to suit panel grid |
| Oil canning risk | Controlled by narrow widths | Higher on large flat faces, needs stiffening or thickness |
| Materials | Zinc, copper, aluminium, Colorbond, UniCote, Corten | Commonly aluminium, also other metals |
The look: line versus plane
The main difference is architectural. Interlocking panels emphasise direction. Vertical panels make a building read taller, horizontal panels stretch it, and diagonals add movement.
Cassettes emphasise the plane. The joint grid becomes a design element that can align with windows, floor lines and structural grids.
Consider how each system turns corners and meets openings. Interlocking panels wrap corners with folded trims or mitred panels. Cassettes can use formed corner trays that carry the joint grid around the building.
Joints and weather management
Both systems are rainscreens. They shed most water at the face, and the membrane and cavity manage the rest.
Interlocking panels have a relatively closed joint. Water that gets past the interlock drains down the cavity. The breathable membrane behind acts as the secondary barrier.
Cassettes with recessed joints rely more on the cavity and membrane. The joint is more open, so the membrane is more exposed to UV and water behind the joint. Specify a membrane rated for open joint facades where relevant, and confirm with the manufacturer.
Panel sizes and oil canning
Oil canning is waviness in flat metal. It is an aesthetic issue, and often the main complaint on flat panel facades. Our oil canning guide covers the causes in detail.
Panel width is the biggest lever. Narrow interlocking panels are stiffer across their width, which is why we cap V25 at 390 mm. Cassettes present large flat faces, so they rely on material thickness, stiffening and a very true subframe.
Glossy and light finishes show distortion more than matt or textured finishes. Pre-weathered zinc and textured coatings are more forgiving.
Substructure
Interlocking panels fix to top hat battens at maximum 600 mm centres. The battens must be set out true, as panel flatness depends on them. Zinc also needs ventilation behind the panels, and a breathable membrane is recommended.
Cassettes hang from an engineered subframe matched to the panel grid. Rails and brackets must be adjustable enough to achieve tight joint lines. The subframe often has to accommodate larger building tolerances.
In both cases, panel flatness and joint lines depend on the substructure, so coordinate it with the builder and engineer early.
Openings and penetrations
Windows, vents and services set out the panel layout as much as the wall dimensions. With interlocking panels, align panel joints with window jambs where possible, so trims return cleanly and panels are not cut to narrow slivers. With cassettes, set the joint grid off the window heads and sills first, then fill the remaining areas.
Group penetrations such as vents and light fittings within a single panel. On cassettes, a penetration near a folded edge weakens the tray and complicates the fixing. Show every opening on the elevations before shop drawings start, as late changes mean refabricating panels.
Cost drivers
Rates depend on the project, so we do not publish them, but the cost drivers are consistent. Interlocking panels mean more panels and more joints per square metre, which adds installation time. Against that, the panels are simple and repeatable to form on our CNC folding equipment, and the battens at regular centres make a lighter substructure.
Cassettes mean fewer, larger panels, but each tray needs four folded edges and corner work. They also need a more complex, engineered subframe and tighter tolerances to keep joint lines straight.
Material choice often has a larger effect than system choice. Zinc and copper generally cost more than aluminium or Colorbond. Complex corners and many openings add cost in either system.
Which system to choose
Choose interlocking panels when you want linear rhythm, want to use zinc or copper in long lengths, or need a system that handles curves and irregular walls. Choose cassettes when you want large flat planes, a strong joint grid, or a solid metal alternative to composite panels.
Both systems are fabricated in our 2,000 m² facility in Sydney using CNC folding, laser cutting and press brakes. Our own drafting team prepares the shop drawings. See completed facades in our projects.
Get advice on your facade
Send us your elevations and we will help you choose between interlocking panels and cassettes, then set out the panel layout on shop drawings. Contact Roofing Group or call 02 9725 1545. You can also draft a system specification with our Spec Builder.