Systems | | 7 min read
Interlocking panel cladding: express joints and setting out
Interlocking metal cladding panels explained: panel widths, express joint options, concealed fixing and how the setting out is resolved before fabrication.

An interlocking panel is a flat tray, 25 mm deep, that hooks onto the panel beside it. One edge carries an extended leg that is screwed to the top hat behind. The next panel steps back, crosses over that leg, turns through 180 degrees and returns underneath, covering the fixing. Nothing shows on the face.
Panels run from 190 mm to 390 mm wide. The joint between them is a design decision rather than a product dimension: flush, or open to as much as 18 mm. That joint is the whole look of the system, and it is the first thing worth resolving.
The express joint
A flush joint gives a near continuous surface with a hairline between panels. An open joint reads as a shadow line, and the wider it goes the more the elevation becomes a series of bands rather than a plane.
Three things follow from the width you pick:
- The cavity is visible at a wide joint. We run a dark backing behind the panel line so the shadow reads as depth rather than as a gap with something behind it.
- Wide joints are more forgiving of tolerance. An 18 mm shadow absorbs a couple of millimetres of movement in the wall behind. A flush joint shows everything.
- Joint width changes the apparent panel width. The same 290 mm panel reads narrower at a flush joint and wider at 18 mm, because the eye groups the shadow with the panel.
Panel width, and why we stop at 390 mm
Standard widths are 190, 240, 290, 340 and 390 mm, and the widths can be mixed across an elevation for a random coursing. We also fold custom widths to suit the site.
We do not go wider than 390 mm. Beyond that, a flat tray starts to show thermal distortion and oil canning, and a facade that looked crisp on the drawing reads as quilted in raking light. If you want a wider module, the answer is a cassette rather than a wider interlocking panel.
Setting out comes before fabrication
Panels are cut to suit the elevation, not the other way round. That means the setting out has to be resolved before anything is folded: where the joints land on window heads and sills, how the coursing meets a floor level or a setback, and which panel absorbs the tolerance at each end of a run.
We draw this and confirm it with the architect. It is the single most useful thing to get right early, because a joint that lands 40 mm off a window head is visible from the street and cannot be fixed on site.
What goes behind
The panel is one layer of a rainscreen, not a waterproof skin:
- Interlocking panel, 25 mm deep
- Galvanised top hats, which set the cavity depth and take the fixings
- Ventilated cavity, open so air can move behind the panels
- Waterproof breathable sarking
- Wall structure by others, able to take the top hat fixings
Water that passes the joint runs down the sarking and out at the base. Air moving through the cavity dries the back of the panel, which is what keeps zinc and the fixings in good order over the life of the building.
Metals and finishes
Zinc, copper, aluminium in PVDF, Colorbond, UniCote LUX and Corten all fold into interlocking panels. Aluminium suits coastal work and holds a set colour. Zinc gives a patina that moves with the weather. UniCote LUX puts a printed timber, stone or corten look on pre-painted steel for sites 400 m or more from the sea.
Solid metal panels are non-combustible, which is a different conversation from aluminium composite panel. We supply the product documentation for the certifier.
Questions we get asked
What is the difference between interlocking panels and cassettes? Scale and fixing. Interlocking panels are long and narrow and hook edge to edge straight onto top hats. Cassettes are large rectangular trays hung on an aluminium subframe with a recess on all four sides, so the grid reads both ways rather than as a run of boards.
Can interlocking panels run horizontally as well as vertically? Yes. The panel is the same either way. Horizontal coursing puts the express joint across the elevation and tends to make a building read longer and lower. Vertical does the opposite.
How wide can the express joint be? Up to 18 mm as standard, and flush at the other end of the range. Anything wider starts to expose the cavity and the top hats behind, so it needs a different backing detail.
Can they be used on soffits? Yes, and it is one of the places the system does its best work, because there are no fixings on the face to look up at. The same panel can run from a wall across a soffit and read as one surface.
Do the panels need a cavity? On almost every assembly, yes. The top hats create it. Metal that stays damp on the back corrodes from behind, which is a problem you do not see until it is expensive, so the ventilation path is not the part to value engineer out.
Can one panel be removed if it is damaged? Panels interlock, so a repair works back from the nearest free edge or an edge trim. It is not as simple as unclipping one panel from the middle of a field. On buildings where that matters, a cassette is the better system.
What thickness do you fold? 0.7 mm for zinc and copper, 0.8 mm for aluminium, 0.55 to 0.7 mm for pre-painted steel depending on the product. We confirm the gauge against the panel width and the wind load for the site.