Systems | | 6 min read
Flat lock cladding: the flattest metal facade you can fold
Flat lock metal cladding explained: interlocking welts on all four edges, panel sizes, substrate requirements and where a flat face beats a ribbed one.

Flat lock is the system for elevations that should be quiet. Nothing stands off the face. There is no rib, no upstand and no exposed fixing. The only line on the wall is the fine recess where one panel meets the next, and it reads as a shadow rather than as a joint.
Each panel is folded with a welt on all four edges. The welt of one panel hooks through the welt of the one below it, so the panels hang off each other, and a concealed clip fixed to the deck holds the assembly back to the building. Panels run to 530 mm wide, with 330 mm and 430 mm as the standard sizes.
Where a flat face is the right answer
Three situations come up repeatedly.
When the form is the design. On a building where the shape is doing the work, a ribbed system adds a texture that competes with it. Flat lock lets the volume read as a single folded plane.
When metal meets another material flush. A rib has to stop somewhere, and that junction needs a flashing. A flat panel can run into render, masonry or glazing with a much simpler detail.
When the panel has to wrap something small. Reveals, blades, fins and soffits are all easier in a small flat panel than in a long ribbed pan.
Curves
Flat lock will follow a radius, and on tight work we help it. We cut grooves into the back of the panel with our laser so the metal has the freedom to curve, and we calculate where those cuts go by modelling the panel in SolidWorks before anything is cut. The face stays uninterrupted; all the work is on the side nobody sees.
That is how a flat panel gets around a curved soffit or a rounded corner without faceting between the folds.
Substrate
Flat lock is the least forgiving system we fold. There is no rib to carry the eye and no shadow line to hide behind, so anything wrong with the wall behind it shows on the face.
The requirement is a continuous, flat, structural deck: 18 mm structural plywood to AS 2269 over studs or top hats at a spacing suited to the wind load, wrapped in a waterproof breathable membrane. Clips at maximum 300 mm centres, confirmed against the site’s wind loads.
If the framing is out, fix the framing. Packing it out behind metal this flat does not work.
Metals
Zinc at 0.7 mm, copper at 0.6 mm, aluminium at 0.7 mm and Corten at 0.7 mm. Zinc is the most specified: the patina is even across a flat field and the surface takes raking light well without the ripple that a wider panel would show.
Copper suits detailed work and tight radii because it forms so cleanly. Aluminium in PVDF holds a fixed colour and suits coastal elevations. Corten is possible, but the runoff stains whatever sits below it and salt air stops the rust layer stabilising, so we keep it away from the coast.
Questions we get asked
What is the difference between flat lock and shingles? The fold is close to identical. The difference is format and coursing. Shingles are small panels in a repeating pattern, usually square or diamond, laid in courses. Flat lock panels are larger and typically rectangular, set out to the elevation rather than to a pattern. If you want the panel grid to disappear, flat lock. If you want the pattern to be the facade, shingles.
How flat is flat? Flatter than any other system we fold, but metal is metal. A large flat panel in raking light will show some movement in the surface. Panel width, substrate flatness and clip layout control it, and all three are decided before fabrication.
Can flat lock be used on a roof? On a wall, a soffit and a steep roof, yes. It is not a low pitch roofing system. For a roof that sheds real water, standing seam or snaplock is the right call.
Can it curve? Yes. On tight radii we laser cut grooves into the back of the panel and program the cut positions in SolidWorks so the panel bends without faceting on the face.
How is it fixed? Concealed clips at maximum 300 mm centres, screwed to the deck and covered by the panel above. Nothing passes through the face and there is no sealant across the field.
How big can a panel be? Up to 530 mm wide, with 330 mm and 430 mm as standards. Larger panels are possible but they start to show distortion, and at that point a cassette with a recessed joint is the better system.
Can a single panel be replaced? Panels hook into each other, so a repair works back from the nearest free edge. It is worth keeping spare stock from the original coil at handover, particularly in zinc or copper where a new panel will not match a weathered field.




