Skip to content

Specification | | 7 min read

Atmospheric corrosivity zones for NSW sites: assessing exposure on site

How to assess corrosivity zones on NSW sites: surf, wind, topography and local sources, matching metals to exposure, and maintenance by zone.

Standing seam metal roof on a coastal NSW house with the sea behind

Most metal roofing and cladding products carry an exposure limit. A product rated for a moderate coastal site can fail early, or lose its warranty, on a headland facing breaking surf. Assessing exposure correctly at design stage sets which metals, finishes and fixings you can use, and how often the building will need washing.

AS 4312 grades sites from C1 (very low) to C5 (very high), plus CX (extreme) for surf shorelines with heavy salt spray and some severe industrial or geothermal sites. Our article on corrosion zones and metal roofing in NSW explains each category in general terms. Refer to the standard and the manufacturer’s current guide for the definitions and distances that apply to a product.

Much of metropolitan Sydney away from the ocean falls in the lower to middle categories. Beachfront and headland sites along the NSW coast often sit in the higher ones. The category belongs to the site, and sometimes to one elevation of the building, rather than to the suburb.

Reading the site

Exposure depends on how much salt, moisture and pollution reach the building, and how long they stay on the surface. Walk the site and check each of the factors below.

A house facing an open surf beach receives far more salt than one on a harbour, river or lake shore at the same distance. Onshore winds carry that salt further inland, so note the dominant wind directions and which elevations face them. The windward face of a building often corrodes faster than the leeward face.

Headlands, ridges and cliff tops catch salt laden wind. Dense vegetation, landforms and neighbouring buildings can screen a site, but removing that screening later, for example when a neighbour demolishes, can raise exposure.

Sulfur compounds and other pollutants from heavy industry, ports, rail yards and major roads increase corrosion, so note any such sources upwind. Geothermal activity is uncommon in NSW but raises corrosivity where present. Closer to home, check for local sources that act like a small severe zone: pool plant rooms, chlorinated pools and spas, commercial kitchen exhausts, cooling towers and stored chemicals.

On the building itself, soffits, eaves, balcony ceilings and walls under deep overhangs get no rain washing. Salt concentrates there. On a coastal site, these surfaces can behave as though they sit in a higher category than the open roof.

Why exposure varies within one suburb

Two houses in the same coastal suburb can need different specifications. One may face the surf on a ridge; the other may sit behind a hill in a sheltered gully. A block from the beach can still be exposed if it is elevated and open to onshore wind. A beachfront apartment’s street elevation may see less salt than its ocean elevation. Assess each site, and each elevation where the difference is large.

Matching metals and finishes to zone

The table gives a general guide only. Product ratings differ between manufacturers, alloys, coatings and grades. Always confirm exposure limits with the manufacturer’s current guide before specifying.

Material C1 to C2 C3 C4 C5 CX
Zinc Generally suitable Generally suitable Check with manufacturer Check with manufacturer Check with manufacturer
Copper Generally suitable Generally suitable Generally suitable Check with manufacturer Check with manufacturer
Aluminium (coated or anodised) Generally suitable Generally suitable Check with manufacturer Check with manufacturer Check with manufacturer
Colorbond type pre-painted steel Generally suitable Generally suitable Check with manufacturer (product specific) Check with manufacturer Not recommended
Corten Generally suitable Check with manufacturer Not recommended Not recommended Not recommended

Corten is generally not recommended near salt. Its protective rust layer needs dry periods to stabilise, and chlorides keep it active, so it continues to corrode.

Material warranties vary by manufacturer, product and site exposure, including distance to the coast. A site in a higher category may carry a shorter warranty, or none, for the same product.

Fixings, flashings and accessories

Match every component to the zone. Stainless clips under the pans will not save a gutter or flashing rated for a lower category. Specify stainless steel fixings and clips where the system calls for them, and check that flashings, gutters and accessories carry a rating for the site. Avoid mixing dissimilar metals, especially in wet, salty conditions.

Maintenance by zone

Exposure sets the maintenance schedule as well as the material.

  • C1 to C2: annual inspection; wash unwashed areas typically once a year.
  • C3: annual inspection; wash unwashed areas typically every 6 to 12 months.
  • C4 to C5: inspect at least twice a year; manufacturers typically recommend washing unwashed areas every 3 to 6 months.
  • CX: follow the manufacturer’s guide closely; washing is often more frequent still.

Record the assessed category in the project documents and the owner’s maintenance manual. If the building’s surroundings change, reassess. See our cleaning and maintenance guide for methods.

Site assessment checklist

  • Distance to the nearest salt water, and whether it is breaking surf or calm water.
  • Direction of prevailing and storm winds, and which elevations face them.
  • Elevation, ridges or cliff tops exposed to onshore wind.
  • Screening by landform, vegetation or buildings, and whether it is permanent.
  • Industrial, port, rail or major road sources upwind.
  • Local sources: pools, spas, plant rooms, kitchen exhausts, cooling towers.
  • Sheltered surfaces on the design that rain will not reach.
  • Manufacturer’s current exposure guide checked for each product, fixing and accessory.
  • Category and maintenance schedule recorded for handover.

Next step

Mark the site’s orientation, distance to the coast and any local sources on your drawings and send drawings for a shop drawing review. We will check each proposed metal against the manufacturer’s current exposure guide. You can compare options with the material advisor, read about zinc, copper, aluminium and steel, or find manufacturer guides on our downloads page.

Start your next project.

Send drawings or a brief. Concept sketches are enough to get a useful answer.

  1. You send drawings or a brief

    A plan, a section and an elevation are enough.

  2. 1business day

    An estimator replies

    Named contact, not a queue.

  3. 7days

    Tender returned

    Priced by system, metal and area.