Materials | | 7 min read
Aluminium cladding for architects: finishes, alloys and coastal performance
Aluminium cladding for architects: PVDF, anodised and natural finishes, alloys, solid sheet vs composite panel, coastal performance and care.

Aluminium cladding is light, formable and naturally resistant to corrosion. It takes a wide range of finishes, from PVDF colours to anodised metallics and textured effects.
The word “aluminium” covers many alloys, tempers and finishes, and each one behaves and ages differently on a coastal NSW site.
Why aluminium
Aluminium forms a thin, tenacious oxide layer as soon as it is exposed to air. That layer protects the metal and reforms if scratched. This gives aluminium good corrosion resistance in many environments, including many coastal ones.
Aluminium is also light. For the same thickness, it weighs around one third as much as steel. That reduces loads on the substructure and makes large panels easier to handle and install. See our aluminium page for the systems we fabricate.
Alloys and tempers
Architectural cladding sheet is commonly made from alloys in the 3000 and 5000 series. The 5000 series contains magnesium and is generally regarded as having better resistance to marine environments. The 3000 series is common for painted coil.
Temper affects formability and stiffness. Softer tempers fold more easily for tight seams. Harder tempers are stiffer and resist dents but may crack on tight bends.
The right alloy and temper depend on the system, the finish and the exposure. Confirm the specific alloy, temper and thickness with the manufacturer’s current technical guide for your system and site.
Finishes: PVDF, anodised and natural
The finish decides the appearance, the colour stability and much of the maintenance regime.
PVDF aluminium
PVDF (polyvinylidene fluoride) coatings are applied to coil in the factory. PVDF aluminium is known for good UV resistance and colour retention. It is available in solid colours, metallics and effect finishes.
VESTIS aluminium, which we have installed on projects, includes finishes such as Aged Copper and Black Graphite. These give the look of other metals with the weight and handling of aluminium. PREFA Patina Grey, used on the Eastgate Shopping Centre standing seam, is another coated aluminium example.
Anodised aluminium cladding
Anodising thickens the natural oxide layer electrochemically. The finish is integral to the metal, not a film on top. Anodised aluminium cladding has a distinctive metallic depth and can be clear or coloured.
Anodised finishes can show variation between batches and between panels. Order from a single batch for each elevation where possible. Folding anodised sheet can also craze the finish at tight bends, so check the system suits post anodised forming or specify anodising after fabrication.
Natural (mill finish) aluminium
Uncoated aluminium weathers to a dull grey. On coastal sites it can pit and develop a white, powdery surface. It is rarely chosen for visible facades where a consistent appearance is expected.
| Finish | Appearance | Colour stability | Coastal notes |
|---|---|---|---|
| PVDF coated | Solid, metallic or effect colours | Good UV and colour retention | Widely used; follow washing guidance |
| Anodised | Metallic depth, clear or coloured | Stable; batch variation possible | Suited with correct alloy and film class |
| Natural (mill) | Dull grey, weathers unevenly | Changes over time | Can pit and whiten in salt air |
Approving finishes
Screen colours and printed swatches misrepresent metallic and effect finishes. Approve finishes on physical samples viewed outdoors, in the orientation they will be installed. Metallic PVDF and some effect finishes are directional, so panels must be installed with the coil direction consistent. Mark the direction on the shop drawings. If you are still shortlisting metals, our Material Advisor compares options by exposure and appearance.
Non-combustibility: solid sheet, not composite
Solid aluminium sheet is a very different product from aluminium composite panel (ACP). ACP bonds two thin aluminium skins to a core, and the core material determines its fire performance.
Our aluminium systems use solid aluminium sheet, not composite panels. Aluminium metal itself is generally considered non-combustible. Coatings are very thin, but facade compliance must still be assessed for the whole assembly, including membranes, insulation and substructure.
Check the current requirements of the NCC for the building class and height. Confirm compliance documentation with the manufacturer and the project’s fire engineer. For a flat panel look without composite material, our cassette system is a common alternative to ACP.
Coastal performance
Aluminium generally performs well near the sea when the alloy, finish and detailing are right. The main risks come from salt deposits, crevices and contact with other metals.
Salt deposits and washing
Salt collects on surfaces that rain does not wash. Soffits, recessed panels, the underside of projections and areas under balconies are typical. Salt holds moisture against the surface and can attack coatings over time.
Manufacturers generally recommend regular washing of these unwashed areas with fresh water and a soft brush. Frequency depends on exposure. Coating warranties commonly depend on following the washing guidance, so confirm the schedule with the manufacturer.
Galvanic contact
Aluminium is less noble than copper and stainless steel. In a salty environment, direct contact can cause galvanic corrosion of the aluminium. Use isolating materials between dissimilar metals and specify compatible fasteners.
Copper runoff is particularly harmful. Never let water from copper drain onto aluminium.
Corrosion zone
AS 4312 classifies sites by atmospheric corrosivity. Very exposed sites near breaking surf may call for a higher specification alloy, a thicker coating or a stricter maintenance plan. Our corrosion zones guide explains the categories.
Weight, thickness and flatness
Aluminium’s lightness is a benefit, but it is also less stiff than steel at the same thickness. Flat panels can show oil canning, a visible waviness across the flat.
To reduce it, keep panel widths moderate, use suitable thickness, and install onto a flat, true substructure. For V25 interlocking panels we limit widths to 390 mm and lengths to around 6 m in aluminium.
Thermal movement is higher in aluminium than in steel. Clips and fixings must allow panels to move.
Maintenance planning
An aluminium facade still needs a maintenance plan that includes:
- Regular fresh water washing of unwashed areas, more often near the coast.
- Periodic inspection of joints, fixings and sealant.
- Checking for debris that traps moisture in channels and at the base of walls.
- Prompt repair of coating damage to the manufacturer’s method.
Talk to us about your aluminium facade
If you are specifying aluminium cladding, send us your elevations and details. Our own drafting team can advise on system, finish and panel layout, and prepare shop drawings. Contact Roofing Group or call 02 9725 1545. Or try our Spec Builder to draft a specification.